OPERATION

MANUAL OPERATION

Operation of the heater is under the direct control of the user. Heat output will, however, be automatically

adjusted in accordance with the room temperature registered by the temperature sensor.

1. Turning Heater ON

A. Press ON/OFF switch to “ON” position. The current room temperature and the set temperature will be

shown on the digital indicator. ON lamp will start to flash and then blower motor and ignition will start. This

lamp will continue to flash during the preheating time.

B. After approx. 1.5 – 4 minutes ignition will take place. (*) After ignition, ON lamp will change flashing to

continuous. Circulation fan will turn on after approx. 2 minutes.

NOTE: (*) Pre -heating depends on the room temperature.

Room temperature:

under 0˚C

4

minutes

0˚C - 15˚C

2

minutes

15˚C

1.5 minutes

2. Adjusting Room Temperature

A. Press “

▲MIN.” or “▼HOUR” button. ˚F or ˚C will start to flash.

NOTE: “

▲MIN.” or “▼HOUR” button will change the temperature in increment of 1˚C (2˚F).

B. Press “

▲MIN.” or “▼HOUR” button as required. Room temperature can be set from 10˚C (50˚F) to 32°C

(90˚F). (Initial setting : 13˚C (56˚F))

NOTE: Desired temperature setting will be displayed on the digital indicator when you set the room

temperature.

C. When room temperature reaches the selected setting, heater will automatically shift

to “MED” or “LOW” burning mode to maintain the desired temperature.

When room temperature exceeds the selected setting by approx. 2˚C (4˚F), the

heater will automatically shut off. As room temperature drops, the heater will

automatically re-start to maintain the desired temperature.

Approx. +2˚C

Approx. +1˚C

SET
TEMP.

High

Medium

Low

Off

Re-lgnition

9

FF_V30T_Type B_US.qxd 14.6.2 11:50 ページ 9