Optional accessory parts – Toyotomi FF-V30T User Manual

Page 21

Advertising
background image

20

Only use genuine Toyotomi parts and accessories, makeshift parts can affect safety and reduce performance. The
Flue Pipe must be used in every installation, and cannot be installed other than through a wall, and with a slight
“fall” to outside. The Flue Pipe is not designed for vertical installation.

There are two ways to extend the Combustion Air and Exhaust Pipe System *….

1) Extension Pipe Kits type (L), (M) and (S)

These stainless steel, telescopic pipe assemblies are designed to create distance between the heater and the
Flue Pipe. They must only be installed by surface (exposed) mounting, inside the heated space and terminate
by connecting to the Flue Pipe which is the only approved means to transport hot exhaust flue gasses to outside.
Extension pipe kits (L), (M) and (S) are provided with an Insulating Cloth Cover for the hot exhaust pipe, but
depending on the site, more insulation may be necessary. Extension pipe kits type (L), (M) and (S) must not be
enclosed, or concealed within a building cavity.
See installation example in “Installation Advice”.

Extension pipe kits (L), (M) and (S) are only suitable for maximum distances (horizontal or vertical) of up to 3 m and
with up to 3 x 90˚ bends, (Elbows). If the distance between the heater and the Flue Pipe is greater than 3 m, then
the proposed installation is unsuitable.

At the “exhaust end” of Extension pipe kits (L), (M) and (S), the Flue Pipe (through a wall) MUST ALWAYS BE
INSTALLED.

Flue Pipe Wall Extension
Flue Pipe Wall Extension
Flue Pipe Wall Extension
L-Shaped Exhaust Joint

17206051
17206052
17206053
17206016

Extends balanced flue from 320 mm to 420 mm
Extends balanced flue from 420 mm to 520 mm
Extends balanced flue from 520 mm to 620 mm
90 degree exhaust pipe bend or “Elbow”

Accessory

Extension pipe kit (L)*
Extension pipe kit (M)*
Extension pipe kit (S)*
L-Shaped exhaust joint*
Exhaust extension pipe 1000
Exhaust extension pipe 500
Exhaust extension pipe 300
Exhaust extension pipe 200
Exhaust extension pipe 100
Exhaust extension pipe (S)

Application

Extends pipe system by 1570 mm to 2000 mm
Extends pipe system by 570 mm to 1000 mm
Extends pipe system by 320 mm to 500 mm
(Elbow) for 90 degree bend in exhaust pipe
Short extension for difficult sites
Short extension for difficult sites
Short extension for difficult sites
Short extension for difficult sites
Short extension for difficult sites
Short extension for difficult sites

Part No.

17206013
17206012
17206011
17206016
17206089
17206083
17206084
17206087
17206088
17206098

OPTIONAL ACCESSORY PARTS

FF_V30T_Type B_US.qxd 14.6.2 11:51 ページ 20

Advertising
This manual is related to the following products: