No.

Name of Part

Q’ty

1

2

3

4

5

6

Adjustable Exhaust Pipe
Max. 1000 mm ~ Min. 570 mm

Intake Pipe (1000 mm)

Insulating Cloth Cover
(1000 mm)

Pipe Holder

Pipe Support Hardware

L-Shaped Exhaust Joint

1

1

1

1

2

sets

1

Extension Pipe Kit (S) PART #17206011

No.

Name of Part

Q’ty

1

2

3

4

5

6

Adjustable Exhaust Pipe
Max. 500 mm ~ Min. 320 mm

Intake Pipe (500 mm)

Insulating Cloth Cover
(500 mm)

Pipe Holder

Pipe Support Hardware

L-Shaped Exhaust Joint

1

1

1

1

1

set

1

(# 17187098)

(# 17212685)

(# 17206004)

(# 17206027)

(# 17206091)

(# 17206025)

Pipe Support Hardware

Pipe Holder (2 pcs.)

Pipe Holder Support (1 pc.)

Screw
(1 pc.)

Wood Screw

(2 pcs.)

Nut (1 pc.)

6

4

5

85 mm

(# 17187098)

(# 17212685)

(# 17206004)

Pipe Support Hardware

Pipe Holder (2 pcs.)

Pipe Holder Support (1 pc.)

Screw
(1 pc.)

Wood Screw

(2 pcs.)

Nut (1 pc.)

6

4

5

85 mm

1

2

3

Max. 1000 mm ~ Min. 570 mm

1000 mm

1000 mm

(# 17206057)

(# 17206091)

(# 17206025)

6

1

2

3

Max. 500 mm ~ Min. 320 mm

500 mm

500 mm

Flue pipe
connection

Intake
Hose

Heater
Exhaust
pipe
connection

Figure 2

Flue pipe
connection

Intake
Hose

Heater
Exhaust
pipe
connection

Figure 3

650 mm ~ 1080 mm

When using the “Extension pipe (M)” extension kit, the distance
between the heater exhaust pipe connection and the flue pipe
connection must be at least 650 mm but no more than 1080 mm. (See
Figure 2 above.)
“Note that Exhaust Extension Kits L, M, and S are designed for
installation inside the heated room, and for exposed (surface)
mounting only”.

When using the “Extension pipe (S)” extension kit, the distance
between the heater exhaust pipe connection and the flue pipe
connection must be at least 400 mm but no more than 580 mm. (See
Figure 3 above.)
“Note that Exhaust Extension Kits L, M, and S are designed for
installation inside the heated room, and for exposed (surface)
mounting only”.

90 mm

90 mm

400 mm ~

580 mm

Extension Pipe Kit (M) PART #17206012

Snow

23

FF_V30T_Type B_US.qxd 14.6.2 11:51 ページ 23