2

Flame Sensor

Heater will automatically stop all operations if ignition fails or if flame fails during combustion, in order to

prevent fuel overflow. Error code will be displayed on the digital indicator.

Overheat Protector

Automatically stops all operations if heater cabinet reaches abnormally high temperature due to motor

malfunction or abnormal combustion, in order to prevent fire.

Power Failure Recovery System

If power fails during heater operation, heater will turn off. When power resumes, heater will

automatically reignite and maintain the normal selected temperature

.

NOTE: The operation varies depending on the time length of power failure and other conditions.

Please see page.14 for more details.

Fully Vented System

Flue pipe system provides outside air for combustion and vents all combustion products to the

outdoors.

1.

2.

3.

4.

SAFETY FEATURES

Your heater is equipped with a number of integral safety features. Please familiarize yourself with these features. If
the heater shuts down due to the operation of any safety device, ensure the problem is identified and corrected.
Note that normal combustion flames inside the combustion chamber, can be seen through some “peep holes”,
located in the front bottom left hand corner of the hot air outlet louver’s.

Burner ring

Burner

Blower motor

Peep hole

Heat exchanger

Igniter

Fuel pump

Fuel sub tank

Removable fuel tank

Flame sensor

Fuel pipe

Overheat protector

Heat shield plate

Fuel acceptance fitting