The following symptoms are normal during operation of the heater.

BEFORE REQUESTING A SERVICE CALL

When heater is started

or extinguished.

When heater is

in operation.

Odor

CONDITION

White smoke or smell inside home when the heater

is first used.

Flashing flames visible in viewing window for a few

minutes after ignition.

Irregular metallic “cracking” noises when when

heater is ignited or extinguished.

Warm air is not discharged as soon as ignited.

Regular pulse “Ticking” noise from heater.

Heat chamber or heat exchanger can be seen

through the air outlet louver’s glowing red hot.

Occasional yellow flickering in blue flame.

Spilled paraffin

Use of inferior paraffin

REASON

Machine oil used in factory assembly, or transit

dust burns off the surfaces of the burner or heat

exchanger.

The burner is cold and igniter is kept running for a

while after.

Expansion / contraction of hot metal components

within the heater warming and cooling.

Delay is to prevent nuisance cool air.

Sound of fuel pump in normal operation.

Normal

Normal

—Wipe off any paraffin spills from fuel sub tank,

removable fuel tank and drip tray.

—Remove fuel and refuel using fresh, water-clear

paraffin.

ERROR CODE

E-0

E-2

E-6

E-8

E-12

E-13

E-22

E-23

FUEL

-- : --

Hi

Lo

INFORMATION

Power failure (low voltage, unstable frequency)

Ignition safety feature is activated.

Extinguished during operation.

Blower motor malfunction

Overheating safety feature is activated.

Burner thermistor malfunction

Excess fuel in the burner

Ignition failure three times

Primary flame rod (Flame sensor) is malfunction and/or dirty

No fuel

Timer is not setting.

Room temperature is higher than 35˚C (95˚F).

Position of room temperature sensor is not correct.

Room temperature is lower than -10˚C (14˚F).

Room thermistor malfunction or disconnected.

WHAT TO DO

Check power source.

Contact your dealer.

Contact your dealer.

Contact your dealer.

Clean the air filter and remove dust.

Contact your dealer.

Contact your dealer.

Contact your dealer.

Consult your dealer.

Refill fuel.

Set the timer.

Check the position of room temperature

sensor. / Contact your dealer.

Check the position of room temperature

sensor. / Contact your dealer.

SECTION G:
TROUBLESHOOTING

17

FF_V30T_Type B_US.qxd 14.6.2 11:51 ページ 17