5 error answer, Picture 5 : error answer example – Analog Way MIDRA PLATFORM TPP Current Programmer's Guide User Manual

Page 9

Advertising
background image

9

PROGRAMMER'S GUIDE FOR v01.02.11

2.4.5 Error answer

When an invalid read or write command string is received, the machine ignores it, answers with the

previous value (unless in case of command error) and immediately answers with one of the following error
string.

Picture 5 : error answer example

Error message structure :

An error message is made of the capital letter E followed by a 2 digits value depending on the error and

is ended with

C

R

L

F

characters. (ASCII 0x0D and 0x0A)

Here are returned error code and conditions covered :

E10 : means “command name error”. It is usually due to a command field (i.e. five letters) that
does not match any legal command string.

E11 : means “index value out of range”. It is usually due to a wrong index value.

E12 : means “index number error”. It is usually due to an incorrect number of indexes, too or
not enough.