Installation (for qualified installers only)

11

© Travis Industries

4140813

100-01294

Leveling Bolts

This heater includes
front and rear leveling
bolts to accommodate
fireplaces with a step-
down firebox.

NOTE: To access the
rear leveling bolts,
remove the cover plates
and gaskets (replace
after adjustment).

Electrical Requirements

 Route the power cord out of the access hole on the right side of the appliance.
 Plug the power cord into a grounded 120 Volt outlet (do not remove the grounding pin).
 The electrical connection may also be made using the optional Wiring Kit (SKU 97200315).
 The appliance, when installed, must be electrically grounded in accordance with local codes or, in the

absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1
.