Installation (for qualified installers only)

9

© Travis Industries

4140813

100-01294

Top Convection Deflector

Install the top convection deflector as
shown to the right.

The deflector is shipped on top of the
insert. The screws are shipped inside
the owner's pack.

Fireplace Requirements

 Insert must be placed within a code-conforming masonry fireplace or tested and listed factory-built

(metal) wood-burning fireplace. Repair any fireplace damage prior to installation.

 Because the insert uses a circulation blower, clean the fireplace, smoke shelf, and chimney prior to

installation.

 This heater may be placed in a bedroom. Please be aware of the large amount of heat this appliance

produces when determining a location.

Fireplace Sizing

3-Piece Panel

1-Piece Panel

Minimum Height

23-3/4” (604mm) 24-7/8” (632mm)

Minimum Width

31-1/2” (800mm) 32.5” (826mm)

Minimum Depth

14-1/2” (369mm)

or

15” (381mm)

Arched Faces

15-3/4” (400mm)

or

16-1/4” (413mm)

Arched Faces

Hearth Extension

1-1/4” (32mm)

0” (0mm)

The gas and electrical line should be installed prior to

installing the heater.

For tight fits (under 28”) see the section “Removing the

Vent Connector”

See “Leveling Bolts” for details on leveling the heater.

h

Attach the “This fireplace has been altered…” plate to the fireplace (use two screws or other