Installation (for qualified installers only)

© Travis Industries

4140811

100-01331

Clearances

Due to the high temperature of the heater, it should be located out of traffic and away from furniture and draperies.

Minimum

Clearances

k Sidewall to Insert

6"
153mm

l Side Facing

(non-combustible)

5"
127mm

m Top Facing*

(non-combustible)

35.5"
902mm

n 12” Mantel* (combustible

or non-combustible)

36.5"
928mm

n 4” Mantel* (combustible

or non-combustible)

33"
839mm

p Hearth Extension to the

Front

12"
305mm

x Extension onto Hearth

0"
0mm

* Measured from the base of the insert.
NOTE: The non-combustible top facing must
extend 35.5” (902mm) above the base of the
insert or to the bottom of the mantel (whichever
is less).

Mantel Clearances

The maximum mantel depth is 12” (305mm).

NOTE: The combustible area above the facing must not protrude more than 3/4" (20mm) from the facing.

If it does, it is considered a mantel and must meet the mantel requirements listed in this manual.

S ide

W all

C omb

ustib

le

or N

on

-C

om

bu

stible

M

ante

l

C om

bus

tibl

e T

op

F aci

ng

No

n-C

omb

us

tible

F aci

ng

l

k

x

n

m

p

Mantel Height

Above Base of Insert (n)

36"(915mm)

35"(889mm)

34"(864mm)

33"(839mm)

37"+(940mm+)

32"(813mm)

31"(788mm)

0" 1" (26mm)

2" (51mm)

8" (204mm)

7" (178mm)

6" (153mm)

5" (127mm)

4" (102mm)

3" (77mm)

9" (229mm)

10" (254mm)

11" (280mm)

12" (305mm)

Maximum Mantel Depth