Installation (for qualified installers only), Exhaust restrictor – Avalon Firestyles 616 Diamond-Fyre User Manual

Page 16

Advertising
background image

16

Installation (for qualified installers only)

© Travis Industries

4140811

100-01331

Exhaust Restrictor

Set the exhaust restrictor to the position shown in the table below.

NOTE: The appliance will slow down within 5 to 10 minutes of startup due to the bi-metallic damper
closing. Make sure to wait for at least 10 minutes before assessing flame quality.

NOTE: The restrictor positions listed below are based upon laboratory testing. The optimum position may
vary slightly.

Natural Gas

(NG)

Height Position

Propane

(LP)

Height Position

15’ or less

Removed*

15’ or less

Removed*

15’ – 25’

#2 (Stock)

15’ – 25’

#2 (Stock)

25’ – 35’

#3

25’ – 40’

#3

35’ – 40’

#4

* If removing the restrictor, replace the screws into the holes in the firebox ceiling. Place the restrictor
plate near the appliance (in fireplace cavity) so it may be used at a later time if needed.