Installation (for qualified installers only)

7

© Travis Industries

4140811

100-01331

Installation Warnings

Failure to follow all of the requirements may result in property damage, bodily injury, or even death.

This heater must be installed by a qualified installer who has gone through a training program

for the installation of direct vent gas appliances.

The installation must conform with local codes or, in the absence of local codes, the National

Fuel Gas Code, ANSI Z223.1/NFPA 54, or the National Gas and Propane Installation Code, CSA
B149.1.

In Manufactured or Mobile Homes must conform with Manufactured Home Construction and

Safety Standard, Title 24 CFR, Part 3280, or, when such a standard is not applicable, the
Standard for Manufactured Home Installations, ANSI/NCSBCS A225.1. This appliance may be
installed in Manufactured Housing only after the home is site located.

The heater is designed to operate on natural gas, or propane (LP).

All exhaust gases must be vented outside the structure of the living-area. Combustion air is

drawn from outside the living-area structure.

Notify your insurance company before hooking up this heater.

The requirements listed below are divided into sections. All requirements must be met

simultaneously. The order of installation is not rigid – the qualified installer should follow the
procedure best suited for the installation.

Packing List

 Propane (LP) Conversion Kit

 Remote

Control

 "Fireplace Altered" tag (attach to the fireplace)

 46” Flex Line with Adapter and Shutoff Valve

Additional Items Required

 Faceplate

 3" and 4” Diameter Gas Liner with Termination (Kit – sku 96200331)

 Gas Line Equipment (shutoff valve, pipe, etc.)

 Panel

Kit

 Fireback Kit – metal liners only (sku’s 96100926/96100927/96100928)

 Media

If using LP (propane) a conversion kit is required (sku 94400999 – GSR Stepper Motor Kit).

Order of Installation

1. Run gas line to the fireplace.
2. Remove the glass frame.
3. Run vent through fireplace chimney. On larger fireplaces, the vent connector may be left in place. For

smaller fireplaces, remove the vent connector. See “Vent Connector Removal and Installation” for details.

INSTALLATION WARNING: If using an NG tall vent (over 25’) – you must open the
diffuser before attaching the vent. See “Diffuser Adjustment” for details.

INSTALL THE LIGHT SHIELD (ALL FACES EXCEPT SHADOWBOX). The light shield
(shipped with the face) prevents light from exiting the upper grill area. Install this
prior to placing the insert.

4. Place insert into position and attach the gas line and vent.
5. Remove the media tray.

NOTE: If using propane (LP), convert the appliance at this time.

6. Install the firebacks (use one of the following metal firebacks: 96100926, 96100927, or 96100928)
7. Replace the media tray.
8. Install the crushed glass.
9. Install the surround panel (see instructions included with surround panel).
10. Follow the instructions under “Finalizing the Installation.”