Finalizing the Installation

© Travis Industries

4140811

100-01331

Vent Location

 An Exhaust Restrictor is built into the appliance to adjust the flow rate of exhaust gases. This

ensures proper combustion for all vent configurations. Depending upon the vent configuration, you
may be required to adjust the restrictor position. See “Exhaust Restrictor” on page 16.

Vent Configurations

Inlet

Z.C. (Metal) Wood-Burning Fireplace

Inlet & Exhaust Re-Line

(recommended)

Exhaust Only Re-Line

(not recommended)

Direct Vent Cap

Recommended Block-Off
Plate (non-combustible
metal and/or insulation).
Prevents odors from
chimney entering room.

6-5/8" to 3" & 4" Colinear

Adapter & Flashing

A block-off plate must
seal the intake to the
chimney space. This
way air is drawn down
the chimney for
combustion air.

Block-Off Plate
(non-combustible
materials)

NOTE: You may use either re-line configuration with a masonry or zero-clearance fireplace.

Inlet

Masonry Fireplace

Any cracks or
damage inside the
chimney must be
repaired.

Exhaust

Exhaust