Installation (for qualified installers only), Fireplace requirements – Avalon Firestyles 616 Diamond-Fyre User Manual

Page 8

Advertising
background image

8

Installation (for qualified installers only)

© Travis Industries

4140811

100-01331

Fireplace Requirements

 The insert must be placed within a code-conforming masonry fireplace or tested and listed factory-

built (metal) wood-burning fireplace. Repair any fireplace damage prior to installation.

 Because the insert uses a circulation blower, clean the fireplace, smoke shelf, and chimney prior to

installation.

 This heater may be placed in a bedroom. Please be aware of the large amount of heat this appliance

produces when determining a location.

 Do not place insulation or any other material on top of the insert. This may block the upper accent

light ventilation, leading to premature bulb failure.

Fireplace Sizing

Minimum Height

24-1/4” (616mm)

Minimum Width

35” (889mm)

Minimum Depth

16-1/2” (420mm)

Hearth Depth (see

“Hearth Requirements”
on the following page
for full details)

12” (305mm)

The gas and electrical line should be installed prior

to installing the heater.

For tight fits (under 28”) see the section

“Removing the Vent Connector”.

See “Leveling Bolts” for details on leveling the

heater.

h

Attach the “This fireplace has been altered…” plate to the fireplace (use two screws or other

suitable method). You may wish to place it in a location where it will be covered by the surround

panels.

Fireplace Clearances to Gas Insert

Side of Insert to Inside of Fireplace

½” (13mm)

Back of Insert to Inside of Fireplace

½” (13mm)

Top of Insert to Inside of Fireplace

5/8” (18mm)

a

b

c

e

f

g

d

h

a

b

c

d

e

f

g