Finalizing the Installation

21

© Travis Industries

4140811

100-01331

Vent Attachment – Tight Installations

The vent connector is shipped attached to the insert, but must be removed to facilitate tight

installations. See the directions below for installation.

1. Route the flex vent through the chimney from above (leave an extra 3' at the top). Make sure the flex

is thoroughly stretched.

2. Remove the vent connector from the unit and attach it to the flex vent (see the instructions on the

following page).

3. Pull on the flex vent until the vent connector is at the same height as the insert. Temporarily attach

the flex vent to the top of the chimney (leave extra slack).

4. Slide the insert into place, guiding the vent connector into the guides on top of the insert.

5. Attach the vent connector to the appliance (see the following page for details).

6. Remove any excess slack in the flex line and attach the vent termination.