2 introduction, Overview, Listing details – Avalon Firestyles 564 HO GS2 Installation User Manual

Page 2: Massachusetts approval, National fireplace institute, Caution

Advertising
background image

2 Introduction

© Travis Industries

4150330

100-01408

Overview

This manual details the installation requirements for
the 564 HO NB GSR2 fireplace. For operating and
maintenance instructions, refer to the 564 HO NB
GSR2 Owner's Manual (part # 100-01409).

Listing Details

This appliance was listed by Intertek Test Labs to
ANSI Z21.88. The listing label is attached to the
appliance near the gas control valve. A copy is
shown to the right.

Massachusetts Approval

This manual has been submitted to the
Massachusetts Board of State Examiners of
Plumbers and Gas Fitters.

National Fireplace Institute


Report No. B100307498PRT

-001

Control No. 4000515

Certified for USA

and Canada

Te

sted to:

ANSI Z21.88-2009/CSA

2.33-2009 “V

ented Gas Fireplace Heaters”, CGA

2.17-M91, UL

307b-2006 “Gas Burning Heating

Appliances for Manufactured Homes”, and CSA

P

.4.1-09.

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code,

ANSI

Z223.1/NFP

A

54, or Natural Gas and Propane Installation Codes, CSA

B149.1.

This appliance must be installed in accordance with the current Standard CAN/CSA

Z240 MH, Mobile Housing, in Canada or with

the Manufactured Home Constructions and Safety Standard, T

itle 24 CFR, Part 3280, in the United States, or when such a

standard is not applicable,

ANSI/NCSBCS

A225.1/NFP

A

501A, Manufactured Home Installation Standard.

This vented gas fireplace heater is equipped at the factory for use with natural gas. If conversion to propane (LP) is desired,

the

optional factory conversion kit must be used.

This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket,

permanently located, manufactured home (USA

only) where not prohibited by local codes. See owner

’s

manual for details. This

appliance is not convertible for use with other gases, unless a certified kit is used.

This vented gas fireplace heater is not for use with air filters.

Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.

This appliance must be properly connected to a venting system in accordance with the manufacturer

’s installation instructions.

Use only approved coaxial direct vent system to vent this appliance to the exterior

. See owner

’s

manual for approved brands of

venting.

W

A

RNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to

the owner

’s

information manual provided with this appliance. For assistance or additional information consult a qualified

installer

, service agency or the gas supplier

.

CAUTION:

Hot while in operation. Do Not T

ouch. Severe burns may result. Keep children,

clothing, furniture, gasoline and other liquids having flammable vapors away

. Do not operate

this appliance with glass removed, cracked or broken. Replacement of the panel(s) should be

done by a licensed or qualified service person.

VENTED GAS FIREPLACE HEA

T

ER - NOT FOR USE WITH SOLID FUEL

MINIMUM CLEARANCES T

O

COMBUSTIBLES

Fireplace to

Adjacent W

all

W

o

od Floor Beneath Fireplace

Back to Enclosure

12” (305 mm)

0” (0 mm)

0” (0 mm)

Base of Fireplace to Enclosure T

o

p

Sides to Enclosure

Base of Fireplace to a 12” Mantel*

(*See manual for other mantel depths)

56” (1423 mm)

0.5” (13 mm)

48.75” (1239 mm)

Input Rate on “HI” (BTU/Hr)

Input Rate on “LO” (BTU/Hr)

35,000

7,500

35,000

10,400

Minimum Inlet Pressure (inches W

.C.)

Maximum Inlet Pressure (inches W

.C.)

Manifold Pressure on “HI” (inches W

.C.)

11

13”

10”

5.5”

7”

3.5”

For natural gas when equipped with the following drill size orifice: DMS 50 Front - DMS 44 Back

For propane when equipped with the following drill size orifice: 1.10mm Front - DMS 55 Back

This appliance is equipped for use only at altitudes 0-2000 feet (0-610m) in the USA. In Canada, 0-4500 feet (0-1370m).

For altitudes above 2000 feet, the vent configuration, orifice, or combination of both may need to be changed.

See the owner

’s manual for information on making these changes.

Electrical Rating: 1

15V

., 60 Hz, 1.5

Amps

L.P

.

N.G.

L.P

.

N.G.

201

1

2012

2013

Jan.

Feb.

Mar

.

Apr

.

May

Jun.

Jul.

Aug.

Sep.

Oct.

Nov

.

Dec.

Manufacture

Date:

www

.travisproducts.com

0962