Installation, Vent requirements – Avalon Firestyles 564 HO GS2 Installation User Manual

Page 21

Advertising
background image

Installation

(

for qualified installers only)

21

Travis Industries

4150330

100-01408

Vent Requirements

 The gas appliance and vent system must be vented directly to the outside of the building, and never

be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent
gas appliance must use its own separate vent system.

 In addition to the requirements listed here, follow the requirements provided with the vent.
 The fireplace must use the Travis Thimble (sku 250-02318) whenever the vent penetrates a wall.

Other penetrations only require a 1" (25mm) clearance and may use a standard firestop (make sure
the required 1" (25mm) clearance is met).

Vent Clearances

 The vent must maintain the required clearance to combustible materials to prevent a fire. Do not fill

air spaces with insulation.

Sides 1"

(25mm)

Above 4"

(102mm)

Below

1" (25mm)

Altitude Considerations

This heater has been tested at altitudes ranging from sea level to 6,000 feet (1800 M). In this testing we have
found that the heater, with its standard orifice, burns correctly with just an air shutter adjustment.

Failure to adjust the air shutter properly may lead to improper combustion which can create a safety hazard.
Consult your dealer or installer if you suspect an improperly adjusted air shutter.

Horizontal

T ermination

S ee C learances Above

Us e a fires top whenever

pas s ing through a ceiling

V ertical T ermination

Us e a roof flas hing and s torm collar

whenever pas s ing through the roof

Us e a s upport box

on expos ed vent

S ee C learances Above

S ee C learances Above

S ee C learances Above

Required Thimble