for qualified installers only)

29

Travis Industries

4150330

100-01408

Vent Configurations with Vertical Termination (Dancing/DiamondFyre)

NOTE: Travis Industries
strongly recommends using a
6-5/8” diameter vent when
terminating vertically.

 The termination must fall

within the shaded area
shown in the chart. Use the
indicated restrictor and
diffuser positions.

 Up to four elbows (45° or

90°) may be used.

 Only one horizontal elbow

may be used.

.

H1

H2

This is considered a horizontal

elbow (it does not matter

whether it turns right or left).

It may be a 90° or 45° elbow.

This is considered a vertical elbow.

Horizontal length (max. 24’) is calculated

by adding both lengths of horizontal run

(Horizontal Length = H1 + H2).

5 feet (1.5m)

0 feet

0 feet

5 feet (1.5m)

0 feet

20 feet (6m)

20 feet (6m)

5 feet (1.5m)

10 feet (3m)

5 feet (1.5m)

10 feet (3m

)

0 feet

15 feet (4.5m)

20' max (6m)

10 feet (3m)

15 feet (4.5m)

15 feet (4.5m)

20' max (6m)

10 feet (3m)

15 feet (4.5m)

40' max (12m)

25 feet (7.5m)

30 feet (9m)

35 feet (10.5m)

40' max (12m)

25 feet (7.5m)

30 feet (9m)

35 feet (10.5m)

Exhaust Restrictor #1
Intake Restrictor #1
Diffuser #1

Exhaust Restrictor #2
Intake Restrictor #3
Diffuser #2 (OPEN)

Exhaust Restrictor #4
Intake Restrictor #3
Diffuser #2 (OPEN)

Exhaust Restrictor #5
Intake Restrictor #5
Diffuser #2 (OPEN)

Exhaust Restrictor #5
Intake Restrictor #6
Diffuser #2 (OPEN)