Installation, Vent installation, Vent location – Avalon Firestyles DVL Insert EF-2002 to 2005 User Manual

Page 12: Vent configurations

Advertising
background image

1 2

Installation

(for qualified installers only)

Travis Industries

4 0 4 1 0 2 8

1 0 0 - 0 1 1 5 1

Vent Installation

Inlet (3”)

Exhaust (4”)

Inlet

Exhaust

Termination Cap
(Simpson Part # 991)

6-5/8” to 3” & 4” Co-
Linear Adapter (Travis
Part # 98900124)

High-Temp.

Silicone

Apply high-temperature
silicone to the liners on
both ends and secure
with 2 screws.

High-Temp.

Silicone

3” dia. Gas

Liner

4” dia. Gas

Liner

Vent Location

2”

Center Line

Inlet (3” Dia.)

Exhaust (4” Dia.)

Fireplace

Opening

2-1/4”

13-7/8”

16”

13-1/4”

Vent
Configurations

Z.C. (Metal) firebox

Inlet & Exhaust Re-Line

Exhaust Only Re-Line

(recommended)

Direct Vent Cap

(part # 991)

Recommended Block-Off
Plate (non-combustible
metal and/or insulation).
Prevents odors from
chimney entering room.

6-5/8" to 3" & 4" Colinear

Adapter & Flashing

(Travis Part # 98900124)

The block-off plate mus
seal the intake to the
chimney space. This
way air is drawn down
the chimney for
combustion air.

Block-Off Plate
(non-combustible
materials)

NOTE: You may use either re-line configuration with a masonry or zero-clearance fireplace.

Inlet

Masonry Fireplace

Suggestion:
Paint the fireplace cavity
with latex paint to eliminate
the possibility of odors from
the fireplace circulating into
the room.

Any cracks or
damage inside the
chimney must be
repaired.

Exhaust

4" dia.

Gas Liner

Inlet

3" dia. Gas Liner

Exhaust

4" dia. Gas Liner

Advertising