Insert Clearances

Due to the high temperature of the fireplace, it should be located out of traffic and away from furniture
and draperies.

Min. 6”

Side
Wall

Combustible or Non-Combustible Mantel

Min. 6”

Combustible Top Facing

Min. 8-1/2”

Side Facing

Min. 10”

12” Min. (from fireplace opening)

Max. 8”

See “Face
Sizing” Below

The non-combustible hearth
must be as wide as the face
and extend to both sides.

See “Face
Sizing” Below

Mantel Clearances

The mantel must be a minimum 10” above the face and a maximum 8” deep.

NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If it

does, it is considered a mantel and must meet the mantel requirements listed in this manual.

Face Sizing

Lopi Discovery DVL

26”

35-3/4”

Avalon Rosario DVL

26”

35-3/4”

FPX Arched
FPX Artisan
NOTE: Artisan faces
vary in size.

26-1/2”

3-1/2"

34-3/4”

Access

Door

Radius = 45”

FPX 34
Rectangular
Bevel

Access

Door

26-1/2”

34-3/4”

Avalon

Cambridge

DVL

25-7/8”

36-3/4”

37-5/8”

2”

27-7/8”

33-5/8”

FPX 34
Architectural
Faces

Access

Door

36”

27-1/2”

* The decorative braces protrude 1/4”

2-3/8”

2-1/4”

27-1/2”

16-1/2”

Avalon

Craftsman

35-3/4”

27”

Avalon

Victorian DVL

Avalon
Rawhide

27”