Setting dip-switches rs422 – BECKHOFF CX9000 User Manual

Page 32

Advertising
background image

Product overview

30

Embedded PC

RS485 without Echo, Drop-Point ( without Termination)

DIP

Status

Function

1 off

Echo

on

2 on

Echo

off

3 on

Auto

send

on

4

off

Always send on

5

off

Auto receive on

6

on

Always receive on

7 off

Term

on

8 off

Term

on

RS485 with Echo, Drop-Point ( without Termination)

DIP

Status

Function

1 on

Echo

on

2 off

Echo

off

3 on

Auto

send

on

4

off

Always send on

5

off

Auto receive on

6

on

Always receive on

7 off

Term

on

8 off

Term

on

Setting DIP-Switches RS422:

RS422 full duplex end point

DIP

Status

Function

1 on

Echo

on

2 off

Echo

off

3 off

Auto

send

on

4

on

Always send on

5

off

Auto receive on

6

on

Always receive on

7 on

Term

on

8 on

Term

on

Note


The system interface CX9000-N31 can only be used instead and not at the same time with system
interface CX9000-N030.
The system interface CX9000-N30 can only be used instead and not at the same time with system
interface CX9000-N031.