Short Seam Automat 2112-4 Working Instructions

Beisler Automated Sewing Equipment

D.4

Factory settings

D.4.1 Factory settings global parameters

M 01 global parameters 2112-4:

Pos.

Globalparameter 2112-4

Value

Unit

01

TILL CLAMP SIDEWAYS FWD

0.1

sec

02

TILL CLAMP DOWN

0.1

sec

03

TILL VACUUM OFF

0.1

sec

04

THRD LENGTH,BOBBIN FULL

003

m

05

TILL CLAMP INSERTING

0.1

sec

06

SEWING END ->CL.SIDEW.

0.1

sec

07

TIME AFTER CLAMP OPEN

0.1

sec

10

TILL FOLDING CL. CLOSED

0.5

sec

11

TILL FOLDER LIFT UP

0.2

sec

12

TILL FOLDER SWINGS LEFT

0.2

sec

13

IMPULS FOLDER DOWN

0.05

sec

14

CL.OPEN TILL FOLDER UP

0.20

sec

17

TILL TENSION OPEN

0.00

sec

18

DURATION OF TENS. OPEN

0.4

sec

20

DUR.THREAD CLAMP FORW

0.5

sec

21

TILL STACKER TRANSPORT

0.1

sec

22

DUR.SLIDING TABLE OPEN

0.8

sec

23

LIFT.TABLE MOD 00/01-99

0

24

DUR.LIFTING TABLE SINKS

0.99

sec

25

TILL FABRIC CLAMP FORW.

0.0

sec

26

TILL SCISSORS CLOSED

0.0

sec

27

DURATION SCISSORS CUTS

0.0

sec

28

TILL FABRIC CLAMP OPEN

0.0

sec

32

BLOW OUT THE PART

0.5

sec

33

CLAMP MOVES TO STACKER

0.0

sec

35

THREAD CATCH. "UP" POS

200

INC

36

SWITCH ON POS.OF TRIMM.

100

INC

37

TRIMMING SPEED

180

Upm

38

DURATION OF TRIMMING

0.35

sec

39

THREAD CATCH.TURNS BACK

00

INC

40

PROCESS IN STEPS

00

Advertising
This manual is related to the following products: