Trouble shooting

6.1 Overview

In general, if your actual readings are fl ashing there will be a problem with the measurement e.g ineffective control. If the required
reading is fl ashing then there will be a problem with the method of control e.g an actual value is outside one of the lockout values.
(see page 30 for more a detailed explanation)

Nutrient reading low

Contaminated probe

Clean Conductivity probe (see p.31)

pH reading inaccurate

Contaminated probe

Clean pH probe (see p.32). Replace probe if in doubt

Calibration

has

expired

Calibrate

pH

probe

(see

p.25)

6.2 Error Messages

Err

Or

Ur

----

Probe is disconnected or
sensor is damaged

EC or pH temperature is out of
range (0-50°C)

Measurement is under range

Measurement is over range