“Power source switch”

Turns on main power of the control
“Left-Stop-Right” travel direction switch (SA3)

Placing the switch in the selected side causes the machine to move in that particular welding direction.
For automatic travel, the travel switch on the NA3 must be in the travel position. To operate manually, the

switch must be in hand position.
“Speed potentiometer” (SA2)

Accurately adjust travel speeds (cm/min) of

the Girth welder. The speed can be monitored at the control display.
«

US version AGWI-DU would be programmed to display travel speed in IPM (inch per minute)

Normal / full speed travel switch

Activate Girth welder full speed travel when the weld gear is set to “manual” mode or “off”.
“Flux recovery vacuum” switch (SA4)

Turns on power of the vacuum for flux recovery

Inverter ON/OFF
Push buttons switch to power on / off the inverter.

CAUTION: Switching the inverter on and off in short interval could cause damage to the inverter. It is

recommended to not switch on the inverter again for at least 3 minutes after is it turned off

“Lighting switch”

Switch on the hurricane lamp for night operation.

Emergency stop

Push button stops all electronic functions including welding and travel.