High frequency warnings – BUG-O Systems BGW-5000 User Manual

Page 3

Advertising
background image

3

PRECAUTIONS:

1) Some plasma or welding cables are strong sources of high frequency

interference. NEVER lay a plasma or welding cable across the controls of the

machine.

2) Always physically separate the plasma or welding cable leads from the

machine cables. For example, the plasma or welding cable leads should

NEVER be bundled with a pendant cable or the machine power cord. Maxi-

mize the separation between any machine cables and the plasma or welding

cables.

3) Strictly follow the grounding procedures specified for the plasma or welding

unit. NOTE: Some plasma and welding units produce exceptionally large

amounts of high frequency noise. They may require a grounding rod be

driven into the earth within six feet (2 meters) of the plasma or welding unit to

become compatible with an automatic cutting or welding process.

4) If the high frequency is produced using a spark gap, adjust the points so the

gap is as small as possible. The larger the gap, the higher the voltage and

the higher the interference.

5) Some plasma or welding units will inject high frequency interference into the

AC power line. Use separate power line branches whenever possible to

power the plasma or welding source and the machine. Do not plug them

into the same outlet box.

6) High frequency noise may enter the machine through the plasma or welding

supply remote contactor leads. Some plasma and welding sources can

produce noise spikes of up to several thousand volts. These sources are not

compatible with automated cutting and welding equipment. It is recom-

mended that the remote contactor leads on these plasma or welding sources

not be connected to the machine. An alternate solution is to purchase a

separate remote contactor isolation box.

HIGH FREQUENCY WARNINGS

WARNING: HIGH FREQUENCY CAN EFFECT MACHINE

OPERATION AND THEREFORE, WELD QUALITY.

SPECIAL PRECAUTIONS ARE REQUIRED WHEN USING PLASMA,

TIG OR ANY WELDING PROCESS THAT USES HIGH FREQUENCY

TO STRIKE AN ARC.

Read the precautions below before installing and using the equipment.