0 performance specifications, General – Interlink Electronics FSR 400 Series User Manual

Page 20

Advertising
background image

www.interlinkelectronics.com

18

FSR

®

Integration Guide


4.0 Performance

Specifications

Below are typical parameters. The FSR is a custom device and can be made for use outside
these characteristics. Consult us for your specific requirements.

General

PARAMETER

VALUE

NOTES

Force Sensitivity Range

~0.2 to 20N

Dependent on mechanics

Break Force (Activation Force)

~0.2N min

Dependent on mechanics and
FSR build

Part-to-Part Force Repeatability

± 6% of established nominal

With a repeatable actuation
system, single lot.

Single Part Force Repeatability

± 2% of initial reading

With a repeatable actuation
system

Hysteresis

+ 10% Average

(R

F+

- R

F-

)/R

F+

Long Term Drift

< 5% per log

10

(time)

Tested to 35 days, 1kg load

Force Resolution

Continuous

Depends on measurement
electronics

Stand-Off Resistance

> 10MΩ

Unloaded, unbent

Switch Travel

0.05mm

Typical; depends on design

Device Rise Time

<3 microseconds

Measured with drop of steel
ball

Maximum Current

1 mA/cm

2

of applied force

EMI / ESD

Generates no EMI; not ESD
sensitive

Specifications are derived from measurements taken at 1000 grams, and are given as (one standard
deviation / mean), unless otherwise noted.