5 | mic paging – Lencore n.Form: MPI-6 User Manual

Page 10

Advertising
background image

section 2

2.5 | mic paging

8

1.

Connect a MIC to Lencore’s MIC pre-amp.

2.

Connect the audio output of the MIC pre-amp to one of the six audio inputs of the MPI.

3.

Connect the MIC switch wires to one of the six “Page on/off Inputs” terminal blocks.

Each terminal block will trigger a specific page zone as follows:

Input 1 = all-call

Input 2 = zone 251

Input 3 = zone 252

Input 4 = zone 253

Input 5 = zone 254

Input 6 = zone 255

4.

Press the MIC key and make the page.

Note: The zones must be configured with Lencore’s Sound Manager or Reports software (iNET only). For iNET, use
audio input 6 for MIC paging.

figure 3 - page on/off inputs