5 | ramp paging – Lencore n.Form: MPI-6 User Manual

Page 11

Advertising
background image

section 2

2.5 | RAMP paging

9

Use with a RAMP:
Note: DIP switch 5 on the RAMP must be down.
Relay outputs 1-8 can be used to trigger RAMP messages to replace the need for RIB relays. Use relay output 9 for the
Stop relay to the RAMP. To play a message, simply dial the relay number of the message (see chart below). If a RAMP
message is playing but a different message is desired, pressing the “*” will stop the current message from playing and
allow another message to be triggered by simply entering the new relay number for the message.
Output relay DTMF trigger
811 = Relay 1
812 = Relay 2
813 = Relay 3
814 = Relay 4
815 = Relay 5
816 = Relay 6
817 = Relay 7
818 = Relay 8
“*” = Stop

When the RAMP is connected to the single RCA audio input 6, RIB relays must be used (acts the same as an iNET MPI).

The RAMP’s Play relay wires must be connected to Page On/Off Input 1 when using audio input 6.

Wire the relay outputs to the RAMP. Relay outputs 1 through 8 can be used to trigger RAMP messages 1 through 8.

Relay output “9” is used for the RAMP “STOP” function. Connect each “C” to the RAMP “1-COMMON.” Note that all the

“C” terminals can be jumpered together at the MPI and only one wire brought to the RAMP “COMMON.” Connect each

“NO” to the RAMP “START” message number required to play. Connect the “NO” of relay “9” to the RAMP “10-STOP”

terminal. The RAMP Play relay output must be connected to one of the page inputs.

Note: The zones must be configured with Lencore’s Sound Manager or Reports software. For iNET, use audio input 6 for RAMP paging.

figure 4 - relay outputs

IMPORTANT

Advertising