4| phone paging – Lencore n.Form: MPI-6 User Manual

Page 9

Advertising
background image

section 2

2.4| phone paging

7

1.

Plug the analog phone line (RJ11) into the MPI Phone input.

2.

Dial the extension of the phone line. The Status LED will turn on.

3.

Wait for a tone from the MPI then press 00# for an all-call page or the zone number followed by the “#”.

Pressing the “*” while entering a zone number acts as a backspace if a digit was entered incorrectly and “*”
will hang-up after pressing the “#.”

4.

Wait for a tone from the MPI then make the page. Hang up the phone receiver when the page is complete.

The Status LED will turn off.

Note: Use 00 – 240 for all custom made zones (241 – 255 are reserved). Two or three digits may be used for zone

numbers. See the Sound Manager or Reports manual for information on creating zones.

Preceding zeros will be ignored - 01# ~ 1# and 00# ~ 0#.

Telephone input – connect a POTS appearance telephone input to the MPI using an RJ11 connector.

Here is the basic specification for a POTS appearance line:

A CO (central office) POTS line is a 2 wire analog appearance.

1) It is a 2 wire (Tip and Ring) analog appearance.

2) It is configured to be loop start.

3) Battery voltage is 48 Volts.

4) Loop current of 23 milliamps.

5) Must have DTMF signaling capability.

6) Must have hang-up (winking) supervision.

Generally, the use of an FXS card (Foreign Exchange Station) or an ATA card (Analog Telephone Adapter) is required

not an FXO (foreign exchange office) card.

Assign an extension to the port. Calling the extension will activate the paging system

figure 2

Advertising