Lynx Studio Aurora 16 User Manual

Page 22

Advertising
background image

Page 20

3.3.1 Clock settings

Since the Aurora will be the master clock, the SYNC SOURCE should be set to “INT”.

The LynxTWO/ L22 should have the Preferred Clock Source
set to “LStream 1” in the Lynx Mixer Adapter page.

Select the appropriate sample rate for your project. Remember that through LStream you
can get 8-channels at up to 96kHz, but a maximum of 4-channels at rates over 100kHz.

3.3.2 Routing

In this instance, signals from the Aurora’s analog inputs should be routed to
the digital outputs for delivery to the LynxTWO/L22 via LStream. By default
the LSlot output mirrors the digital outputs.
Similarly, the LSlot inputs provide signals from the LynxTWO/L22 via
LStream, and should be routed to the Aurora’s analog outputs, which will be
connected to monitoring equipment. Select “LSLOT” for TO ANALOG
OUT and “ANALOG IN” for TO DIGITAL OUT from the Aurora front
panel.