4 Front Panel Key Combinations



Aurora functionality can be altered via its front panel with key combinations or by depressing certain
front panel buttons for 500ms. Here are some of the possible modifications as of firmware rev 22:

Button

Action

Result

METER

Depress METER button for

500ms

Enables Horizontal Metering Mode. Meters

will display activity for Analog Out 1-4 (if

METER switch is set to “ANALOG”), or

Digital Out 1-4 (if METER switch is set to

“DIGITAL”)

SYNC SOURCE

Depress SYNC SOURCE

button for 500ms

Toggles “Synchrolock” between ON and

OFF

TO ANALOG OUT

Depress TO ANALOG OUT

button for 500ms

With LT-HD card installed in Aurora,

Toggles between 16 and 32 channel mode

(see LT-HD User Manual)

TRIM

Press and hold TRIM button

while turning on

POWER/STANDBY switch

Displays firmware revision in the meter

display (combine rapidly flashing number

from input and output row)

STANDBY/POWER

Press STANDBY/POWER

switch while AC power is

applied

Toggles power up mode between Standby

and On

SAMPLE RATE

Press SAMPLE RATE button

while AC power is applied

Restores factory defaults

TRIM/AES MODE

Press TRIM/AES MODE

button while AC power is

applied

Enables DUAL WIRE SELECT mode, where

the Dual Wire state for the Digital I/O can be

set.