Wire direct wire connection – Maytag WED9051YW Installation User Manual

Page 12

Advertising
background image

12

4.

Connect neutral ground wire and

neutral wire

C

E

B

6.

Connect remaining wires

5.

Connect ground wire

F

A

Connect ground wire (green or bare) (F) of direct wire cable

to external ground conductor screw (A). Tighten screw.

Place hooked ends of remaining direct wire cable wires under

outer terminal block screws (hooks facing right). Squeeze

hooked ends together and tighten screws. Finally, reinsert tab

of terminal block cover into slot of dryer rear panel. Secure

cover with hold-down screw. Now, go to “Venting Requirements.”

Connect neutral ground wire (E) and place hooked end (hook

facing right) of neutral wire (white or center wire) (C) of direct

wire cable under center screw of terminal block (B). Squeeze

hooked ends together and tighten screw.

3-WIRE DIRECT WIRE

CONNECTION

1.

Prepare your 3-wire cable for

direct connection

1"

(25 mm)

3½"

(89 mm)

3.

Remove center screw

B

Use where local codes permit connecting

cabinet-ground conductor to neutral wire.

Remove center terminal block screw (B).

Direct wire cable must have 5 ft. (1.52 m) of extra length so

dryer may be moved if needed.

Strip 3

1

/

2

" (89 mm) of outer covering from end of cable. Strip

insulation back 1" (25 mm). If using 3-wire cable with ground

wire, cut bare wire even with outer covering. Shape wire ends

into hooks.

2.

Attach hooked wires to terminal

block

To connect wires to terminal block, place hooked end of

wire under terminal block screw, facing to the right, squeeze

hooked end together and tighten screw.