DRYER DIMENSIONS

Front view:

Side view:

LOCATION REQUIREMENTS

You will need:

A location allowing for proper exhaust installation.

See “Venting Requirements.”

A separate 30 amp circuit.

If using power supply cord, a grounded electrical outlet

located within 2 ft. (610 mm) of either side of dryer.

See “Electrical Requirements.”

Floor must support dryer weight of 200 lbs. (90.7 kg).

Also consider weight of companion appliance.

Cold water faucets located within 4 ft. (1.2 m) of the water fill

valves, and water pressure of 20–100 psi (137.9–689.6 kPa).

You may use the water supply for your washer using the “Y”

connector and short hose (if needed) which are provided.

20–100 psi (138–690 kPa) for best performance.

Level floor with maximum slope of 1" (25 mm) under entire

dryer. If slope is greater than 1" (25 mm), install Extended

Dryer Feet Kit, Part Number 279810. If not level, clothes

may not tumble properly and automatic sensor cycles may

not operate correctly.

For each arrangement, consider allowing more space for ease

of installation and servicing; spacing for companion appliances

and clearances for walls, doors, and floor moldings. Space

must be large enough to allow door to fully open. Add spacing

on all sides of dryer to reduce noise transfer. If a closet door

or louvered door is installed, top and bottom air openings

in door are required.

27"

(686 mm)

1"

(25 mm)

35

3

/

8

"

(899 mm)

3

1

/

2

"

(89 mm)

29"

(736 mm)

Left or

right side

exhaust

6

7

/

8

"

(174 mm)

1

5

/

8

"

(41 mm)