Maytag WED9051YW Installation User Manual

Page 5

Advertising
background image

5

Door open view:

Back view:

6

1

/

4

"

(159 mm)

28

1

/

8

"

(715 mm)

3

1

/

2

"

(89 mm)

14"

(358 mm)

Electric

NOTE: Most installations require a minimum of 5" (127 mm)

clearance behind dryer for exhaust vent with elbow. See “Venting

Requirements.”

IMPORTANT: Do not operate, install, or store dryer where

it will be exposed to water, weather, or at temperatures below

45° F (7° C). Lower temperatures may cause dryer not to

shut off at end of automatic sensor cycles, resulting in longer

drying times.

Spacing for recessed area or closet installation

All dimensions show recommended spacing allowed, with tested

spacing of 0" (0 mm) clearance on sides and rear.

Additional spacing should be considered for ease of

installation and servicing.

Additional clearances might be required for wall, door, and

floor moldings.

Additional spacing should be considered on all sides of the

dryer to reduce noise transfer.

For closet installation, with a door, minimum ventilation

openings in the top and bottom of the door are required.

Louvered doors with equivalent ventilation openings are

acceptable.

Companion appliance spacing should also be considered.

No fuel-burning appliance may be installed in the same

closet as the dryer.

Closet installation (dryer only):

24 in.

2

(155 cm

2

)

48 in.

2

(310 cm

2

)

1"

(25 mm)

1"

(25 mm)

4"

(102 mm)

3"

(76 mm)

34" recommended

(864 mm)

18" min.

(457 mm)

3"

(76 mm)

Cabinet installation (dryer only):

1"

(25 mm)

1"

(25 mm)

4"

(102 mm)

7"

(178 mm)

18"

(460 mm)

47

1

/

8

"

(1197 mm)

48

1

/

8

"

(1238 mm)