VENTING REQUIREMENTS

VENTING

WARNING:

To reduce the risk of fire, this dryer MUST BE

EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.

Dryer exhaust must not be connected into any gas vent,

chimney, wall, ceiling, attic, crawlspace, or a concealed space

of a building. Only rigid or flexible metal vent shall be used for

exhausting.

Only a 4" (102 mm) heavy metal exhaust vent and clamps

may be used.

Do not use plastic or metal foil vent.

Rigid metal vent:

Recommended for best drying performance and to avoid

crushing and kinking.

Flexible metal vent:

(Acceptable only if accessible to clean)

Must be fully extended and supported in final dryer location.

Remove excess to avoid sagging and kinking that may

result in reduced airflow and poor performance.

Do not install in enclosed walls, ceilings, or floors.

The total length should not exceed 7

3

/

4

ft. (2.4 m).

NOTE:

If using an existing vent system, clean lint from

entire length of the system and make sure exhaust hood

is not plugged with lint. Replace plastic or metal foil vents

with rigid metal or flexible metal vents. Review “Vent System

Charts” and if necessary, modify existing vent system to

achieve best drying performance.

Louvered Hood

Good

Angled Hood

Box Hood

Better

4"

(102 mm)

4" (102 mm) heavy metal exhaust vent

Exhaust hoods:

Elbows:

Recommended Styles:

Recommended Styles:

45° elbows provide better airflow than 90° elbows.

Clamps:

Use clamps to seal all joints.

Exhaust vent must not be connected or secured with screws

or other fastening devices that extend into interior of duct

and catch lint. Do not use duct tape.

Must be at least 12" (305 mm) from ground or any object that

may obstruct exhaust (such as flowers, rocks, bushes, or

snow).

Acceptable Style: