MBM Corporation CREASEMATIC AUTO 50 User Manual

Page 29

Advertising
background image


5. Paper does not feed:

5.1. Ensure compressor is on.
5.2. Ensure side lay are not too tight
5.3. Ensure paper stack is “floating”.
5.4. Check gate position.
5.5. Check throttle position.
5.6. Ensure suction relay (leftmost small relay) has actuated. Relay with grey wire to

right of 11 pin. Contacts are up.

5.7. Ensure suction valve has operated. I.e. solenoid has “pulled in”
5.8. Check setting of solenoid for suction valve. Release valve body cap (two 5mm

set screws) to allow a 1mm gap between the cap and the body. Loosen the the
hex bolts holding the solenoid block to the cover plate. Pull the solenoid block
away from the valve until there is no slack in the system. Tighten hex bolts. Now
tighten set screws in cap. This last action will force the solenoid bolt out of the
solenoid.


From
Compressor

Solenoid

To Wheel

Spring Stop

Return Spring

Valve Body

Auto50-ops-touch screen usa

4/3/2013

29