8-6 Taking Measurements

898095

DaqScan/2000

Series

Synchronizing Multiple Units

Up to four DaqScan/2000 Series devices can be synchronized to each other via their rear

panel SYNC connectors and associated cables. Each device has two identical SYNC ports;

either [or both] can be used to connect units. The DaqScan units can be scan-synchronized

and triggered from any other SYNC-connected unit. Note that cables CA-74-1 and CA-74-5

are 1-foot and 5-foot in length, respectively. The total combined cable length of the Sync

cables is not to exceed 15 feet (4.57 m).

Synchronization Concept Block Diagram

The preceding diagram shows how a DaqScan/2000 Series device can input or output

synchronization timing and trigger events on either SYNC connector. A more detailed block

diagram follows shortly.

Reference Notes:

¾ The SYNC features are programmable via software. For detailed information

see the Using Multiple Devices and the daqAdcSetClockSource sections of the

Programmer’s Manual (p/n 1008-0901).

¾ During software installation, Adobe

®

PDF versions of user manuals

automatically install onto your hard drive as a part of product support. The

default location is in the Programs group, which can be accessed from the

Windows Desktop. Refer to the PDF documentation for details regarding both

hardware and software.

Synchronization Model for DaqScan/2000 Series Devices

(see note)

Note: DaqScan/2002 and DaqScan/2004 have no P1 connector; thus the pin 20

and pin 25 lines do not apply to those two devices.