Installation – Montigo H38DF ST User Manual

Page 15

Advertising
background image

H*38DF ST Indoor Gas Fireplace

Page 15

XG0207 - 150204.1

Installation

Flex Section

Heat

Shield

Termination

Exterior

Wall

Hearth

Solid Section

126” Max.

30” Max.

Figure 13c. Top Vented, wall mounted Retracted Multi-elbow installation. See

Venting Graph for Top vent, wall mounted terminations, Figure 13.

Notes Wall Mounted Terminations: SIDE VENT

„

All dimension lengths for vertical or horizontal runs are measured

from centre of the vent pipe.

„

Venting runs must fall within the limits set by the venting graphs,

see Figure 14.

„

Fireplace must be converted to Side Vent configuration prior to

running vent, see Figure 9 and 9a.

The Venting Graph

Measure the vertical height from the fireplace hearth to the centre of the

termination and the horizontal run from the fireplace flue collar to the wall

flange of the termination. Plot on the Venting Graph Figure 14 with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the

installation is acceptable.
Example A: (Acceptable Installation)

If the vertical dimension from the hearth is 120" and the horizontal

run to the wall flange of the vent termination is 138", this would be

an acceptable installation.

Example B: (Unacceptable Installation)

If the vertical dimension from the hearth is 48" and the horizontal

run to the wall flange of the vent termination is 96", this would

NOT be an acceptable installation.

Example C: (Unacceptable Installation)

If the vertical dimension from the floor of the fireplace is 72" and

the horizontal run to the wall flange of the vent termination is 120",

this would NOT be an acceptable installation.

Figure 14. Side Vent Venting Graph for wall mounted terminations.

A

C

48”

42”

33 1/2”

12”

Unacceptable vent run

within shaded area.

Acceptable vent run

within non-shaded area.

120

132

B

C

A

If your installation does not fall within

the venting graph parameters,

please contact a local Montigo dealer

for Power Venting Options.

Figure 14a. Straight run, Side Vented, wall mounted termination for H*38DF*-

ST, Figure 14.

33 1/2”

PXT Extension

Heat

Shield

Termination

Hearth

Exterior

Wall

NOTE:

12” MAX. horizontal

run with no vertical lift.

12” MAX.

Figure 14b. Side Vented, wall mounted Multi-elbow termination installation.

Installation for H*38DF*-ST must have a minimum vertical rise of 48". The

vent run must comply with the Venting Graph for Side vent, wall mounted

terminations, Figure 14.

30” Max.

12”

Max.

Flex or Rigid

Section

14 1/2”

Min.

Hearth

33 1/2"

48" Min