Troubleshooting, Sit nova 820, Honeywell – Montigo H38DF ST User Manual

Page 32: Sit proflame 2, Maintenance

Advertising
background image

H*38DF ST Indoor Gas Fireplace

Page 32

XG0207 - 150204.1

Maintenance

Honeywell:

The following is a troubleshooting chart of possible problems:

If your fireplace still does not operate correctly, consult your local

Montigo dealer.

All service and repairs should be performed by a qualified

Technician.

All spare parts, optional fans, and optional trim finishes are available

from your local Montigo dealer.

SIT Proflame 2:

The following is a troubleshooting chart of possible problems:

Troubleshooting:

SIT Nova 820:

The following is a troubleshooting chart of possible problems:

PROBLEM

CORRECTIVE ACTION

Noisy Pilot Flame

Locate pilot adjustment screw on

gas control valve. Flame is decreased by

turning adjustment screw clockwise.

Pilot won’t ignite

Disconnect remote wires and try to

light pilot. If pilot now works, remote

connections are faulty. Check wiring

diagram figure

30.

Main burner will

1. Check wiring (see figure 30).

not light

2. Check wall switch for proper

connection.

PROBLEM

SOLUTION

Pilot Igniter won't spark

1. Check the MAIN ON-OFF switch

(typically located below the valve cover)

and turn ON
2. Ensure main power is ON or new

batteries are installed in the remote

control and backup battery pack (if

available).
3. Check the 3.15A fuse in the control

box and replace if necessary

Pilot Igniter sparking, but

Pilot burner will not light

1. Verify the Inlet and Manifold Gas

Pressure are within acceptable limits
2. Check all connections to gas valve
3. Check connection to stepper motor

(if available)

Pilot lights , but Main burner

will not Light

1. Check and verify all wiring connections

as per the wiring diagram.
2 . Verify the inlet and Manifold Pressure

are within acceptable limits

Pilot lights , but Main burner

will not Light and igniter

continues to spark

1. Check the Pilot Flame Sensor Rod

and clean with steel wool or similar.
2 . Check the Pilot hood and clean with

steel wool if dirty.
3. Adjust pilot flame using the pilot

adjustment screw if the pilot flame is

too long or too short (Flame should

fully engulf the sensor rod and must

be stable).
4. Check and make sure the ground

wire from the pilot is connected to the

fireplace body.

Fans not working

1. Ensure main power is ON (fireplace

may be operating on back up batteries).
2. Check the 3.15A fuse in the control

box and replace if necessary

Advertising
This manual is related to the following products: