Installation

Section 2: Framing

1).

Frame in the enclosure for the unit with framing materials. The

framed opening for the assembled fireplace is 40¾" wide, x 42½"

high x 23¾" deep, see Figure 2

.

NOTE: When constructing the framed opening, please ensure there is

access to install the gas line when the unit is installed. See Figure 21.

Figure 2. Framing dimensions, (Both Sides Typical).

Figure 5. Combustible Framing for shelves over the fireplace, Top vent.

Figure 4. Combustible Framing for shelves over the fireplace, Side vent.

Figure 6. Non Combustible Framing with alcove above fireplace, Right side.

Combustible Framing above fireplace, Left side, see figure 2 (Top Vent).

10”

Min.

Combustible Shelf

33 1/2”

42 1/2”

Exterior

Wall

Combustible Header

Combustible material Backframe,

2-pieces. Both Sides Typical.

Floor

36 1/2”

42 1/2”

Combustible

Header

Min. 1 ”

10”

Ceiling level

Non-Combustible

Header

Non-Combustible

materials. Alcove

over fireplace.

Non-Combustible Nail-

ing Flange, (supplied).

Both sides Typical.

See figure

Top Vent

6"

40 3/4”

Figure 3. Securing the fireplace to the framing cleats.

8.

40¾” (rough opening)

23¾”

42½”

Both walls Typical. May

not be exactly as shown.

Combustible material

Backframe, 2-pieces. Both

Sides Typical. See figure 3.

46” Min

17 1/2”

Min.

PEL Short

90 elbow

Combustible Shelf

Combustible Header

Combustible material Backframe,

2-pieces. Both Sides Typical.

42 1/2”

Note: Images are shown without screens for clarity purposes. However,

your fireplace should not be operated without proper installation of

screens.