Section 4: installing the power vent, Venting layout, Straight venting layout – Montigo R320-ST User Manual

Page 13: Multi-elbow installations, Downward vertical venting, Installation

Advertising
background image

Section4:InstallingthePowerVent

Figure 2 Sec.4 Multi-elbow Venting Installations.

Multi-Elbow Installations

Multi-elbow installations are possible up to a maximum of six

at 90° elbows.

Figure 3 Sec.4 Downward Venting Installations.

Downward Vertical Venting

Note: The downward vent run must not exceed 6' of vent run.

Figure 1 Sec.4 Typical straight Venting Installations.

Montigo supplies a variety of power venting options. The location of

the power vent should be selected and laid out to provide the shortest

possible run to an external wall or through the roof.

Installing a Roof Mounted Vertical Exterior

Power Vent

This section applies to installations where the shortest possible vent

run is through the roof. Refer to

AppendixA -PowerVentlocations,

to ensure the planned Power vent location is acceptable. Once the

vent location has been established, please refer to the appropriate

section below for installation details.

Venting Layout

Selection of components and details of venting lay out should adhere

to the following guidelines:

■ Ensure there is a minimum run of 2’ of straight pipe before

the power vent

■ Ensure the maximum vent run does not exceed 80’

■ Ensure the number of 90° elbows does not exceed 6

■ Ensure the number of 45° elbows does not exceed 12

Straight Venting Layout

Venting Installation

V(MaximumLength) Max.#Elbows

80 Feet

6

MultiElbow-VentingInstallation

V1 + H1 + V2 + H2 + V3

(MaximumLength)

Max.#

Elbows

40 Feet

6

V

Elbow 1

Elbow 2

Elbow 3

Elbow 5

Elbow 4

H2

H1

V1

V2

V3

Elbow 1

Elbow 2

Elbow 3

Elbow

H1

V1

D = 6’ foot

MAX

V3

H2

Elbow 4

MultiElbow-VentingInstallation

V1 + H1 + V2 + H2 + V3

(MaximumLength)

Max.#

Elbows

80 Feet

6

Note: Images are shown without screens for clarity purposes.

However, your fireplace should not be operated without proper

installation of screens.