Mantels & Surrounds

NOTE: National Canadian Gas Association mantel test requirements

are for fire hazard prevention to combustible materials.
New technology, to meet consumer and government demands for the

wise use of energy, has prompted us to manufacture many models

of fireplaces which are hot, fuel and energy efficient.
Please be aware; temperatures over the mantel will rise above normal

room temperature and walls above fireplace may be hot to touch.
We recommend careful consideration be given to the effects of

elevated mantel temperatures which may be in excess of product

design, for example: candles, plastic or pictures. This can cause

melting, deformation, discoloration or premature failure of T.V. and

radio components.

Side wall clearances are 6". Combustible surrounds may be installed

with 6" clearance to the side of the fireplace as shown in

Figure2Sec.7.

Figure 2 Sec.7 Combustible surrounds.

Non-combustible Header

6”

15

½”

Drywall Sheetrock

15 1/2” Non-Combustible

Facing Material

Note: Images are shown without screens for clarity purposes.

However, your fireplace should not be operated without proper

installation of screens.

R320-ST & R420-ST Power Vent Indoor Gas Fireplace

Page 22

XG0774 - 150121