Installation and repairs should be done by an authorized gas fireplace service technician.

The appliance should be inspected before use and at least annually by a professional. More

frequent cleaning may be required due to excessive lint from carpeting, bedding material,

etc. It is imperative that control compartments, burners and circulating air passageways of

the fireplace are kept clean.

NOTICE

IMPORTANT MESSAGE: SAVE THESE INSTRUCTIONS
The

R320-ST & R420-ST Power Vent fireplaces must be

installed in accordance with these Instructions. Carefully read

all the instructions in this manual first. Consult the Local Gas

Branch to determine the need for a permit prior to starting the

installation. It is the responsibility of the installer to ensure this

fireplace is installed in compliance with the manufacturers

instructions and all applicable codes.

BEFORE YOU START:

Pre-Installation Checklist

■ Determine the desired install location of your fireplace.

■ See Section 1, Dimensions on Page 5, and refer to the

Framing Section 2 for details.

■ Select your type and location of your Power Vent

run: Roof Mounted PVVEX58-300, External Wall

Mounted PVHEX58-300, Flush Louver Wall Mounted

PVHFL58-300, Inline Power Vent (PVHIN58-300) with

flush louvered termination (TMHIN48-40).

■ Your termination location should be selected to provide

the shortest possible vent run.

■ Lay out the Vent run; calculating the required elbows

and straight runs of 5"/8" flex and/or rigid pipe.

■ Refer to the Section 4 on Page 10, "Installing the Power

Vent" for details.

■ Montigo supplies 20' of low voltage wire, which can be

spliced to any length. This wire CANNOT run in conduit

with any other wire.

■ Refer to Section 5 on Page 18, for Wiring Details.

■ The gas connection is located on the bottom side of the

fireplace.

■ Refer to local codes and guidelines for installation

requirements.

■ Installation and repairs should be done by a qualified

contractor and must conform to:

•InstallationsinCanada must conform to the current

CAN/CGA B-149.1 and .2 Gas Installation Code and

local regulations.

•InstallationsintheUSA must conform to local

codes, or in the absence of local codes to the National

Fuel Gas Code, ANSI Z223.1-1988.

•SeeAppendixCforinstallationwithintheState

ofMassachusetts. This fireplace must comply with

NFPA-54 Chapter 10.

■ Refer to Section 6 Page 21, "Installing the Gas Line" for

Details.

Understanding the Basic Operation

Residential R320-ST & R420-ST fireplace

The control compartment of this fireplace is located in the bottom

of the fireplace right below the burner system. All models will

be supplied with a Honeywell smart valve gas control and will

not have a variable flame control. There are two air switches

that are controlling the gas control system, and are located in

the bottom of this fireplace. These gas valves, and pressure

switches communicate with the electrical control panel via a six

conductor cable supplied with the fireplace.
To operate the fireplace, Montigo has supplied and installed

twenty feet of low voltage wire to this electrical control panel.

Connect the two wire harness to a standard single pole ON/

Off switch located at a location of your choice. You may also

extent these wires to any length, as long as you select a wire

of equal quality.

Due to high operating temperatures, this appliance should be located out of traffic &

away from furniture and draperies.

Children and adults should be alerted to the hazards of the high surface temperature,

which could cause burns or clothing ignition.

Young children should be carefully supervised when they are in the same room as the

appliance.

Clothing or other flammable materials should not be placed on or near the appliance.

CAUTION

When this appliance is installed directly on any combustible material other than wood

flooring, it must be installed on a metal or wood panel extending the full width and

depth of the appliance or a fire will occur causing serious injury, property damage or

even death.

DANGER

WARNING

A barrier designed to reduce the risk of burns from hot viewing glass is provided with this

appliance and shall be installed for the protection of children and other at-risk individuals.

If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s

barrier for this appliance.

WARNING

Any safety screen, guard, or barrier removed for servicing an appliance must be replaced

prior to operating the appliance.

R320-ST & R420-ST Power Vent Indoor Gas Fireplace