Section 6: installing the gas line, Fuel type, Gas pressure – Montigo R320-ST User Manual

Page 20: Gas connection, Installation

Advertising
background image

Figure 1 Sec.6 Gas Inlet Supply location.

Fuel Type

Verify that your fireplace is compatible with your available gas type.

Natural Gas or Propane shown by "N" or "L" in your model number

on rating plate.

Gas Pressure

The manifold outlet pressure is set from the factory to the appropriate

pressure but should be verified.
To check pressures, control valves have a provision to remove a 1/8”

N.PT. plug to be fitted with a hose barb.
Montigo requires a service shut off valve be located in an accessible

location to isolate the gas supply.
Only install gas shut-off valves approved for use by the state, province,

or other governing body in which the fireplace is being installed.

GAS CONNECTION

See

Figure1Sec.6below for location of gas line access.

Flexible gas connectors must not exceed 3 feet in length, unless

allowable within local regulations.
Connect incoming gas line to the 1/2" Male NPT gas inlet.
Purge all air out of gas line before connecting port.
Check appliance connection, valve and valve train under normal

operating pressure with a commercially available leak check solution.
DONOTUSEAFLAMEOFANYKINDTOTESTFORLEAKS.

Pressure Requirements

Gas Pressure

Natural Gas Propane

MinimumInletPressure 5.5" W.C.

11" W.C.

Manifold Pressure

3.5" W.C.

10" W.C.

Section6:Installingthegasline

1

¾”

1/2” MPT gas

inlet

Figure 2 Sec.6 Identifying the Gas Inlet and Combustion Air Switch Sensor Line

Located next to the Gas Inlet is the Combustion Air Switch Sensor

Line.
Do NOT obstruct or alter the Combustion Air Switch Sensor Line.

R320-ST & R420-ST Power Vent Indoor Gas Fireplace

Page 20

XG0774 - 150121

Installation

Advertising
This manual is related to the following products: