Venting components, Heat shields, Installation – Montigo R320-ST User Manual

Page 16

Advertising
background image

Venting Components

The following venting components and associated Montigo part

numbers are available for horizontal installations:

Connectionandinstallationoftheventcomponentsshould

adheretothefollowingguidelines:

■ Connect all vent sections using a minimum of three sheet

metal screws on the outer pipe flue.

■ Ensure the pipe ends male to female slide in a minimum

of 1 1/2“ of overlap.

■ Ensure all runs are supported with a minimum of 3 supports

per 10’ of venting.

■ When hanging/ supporting venting, ensure that 1” clearance

is maintained on all sides to any combustible material.

■ Ensure when cutting sections of rigid pipe to maintain

integrity of internal supports.

■ Place the springs, supplied with the pipe kit, between the

outer and inner pipes to keep the pipes separate and avoid

any possible hot spots.

■ Montigo recommends the use of a flex section for the final

pipe connected directly to the fireplace offering greater

flexibility of installation and absorption of movement.

■ All exterior joints in venting should be sealed with high heat

silicone RV230.

Installation of the horizontal power vent module.

Note: See power vent manual for installation instructions.

Refer to Appendix A - Power Vent locations, to ensure the planned

Vertical Power vent location is acceptable.

A - Termination

PVHEX58-300 Wall Mount 5"/8"

PVHFL58-300 Flush Wall Mount

5"/8"

PVHIN58-300 Inline Power Vent

with TMHIN58-40 termination

C - Flex Sections

PFL1 (12" f/f Section)

PFL2 (24" f/f Section)

PFL3 (36" f/f Section)

PFL4 (48" f/f Section)

PFL6 (72" f/f Section)

D - Rigid Sections

PXT - 10 (10" f/f Section)

PXT - 20 (20" f/f Section)

PEXT - 1 (12" f/m Section)

PEXT - 2 (24" f/m Section)

PEXT - 3 (36" f/m Section)

PEXT - 4 (48" f/m Section)

PEXT - 6 (72" f/m Section)

E - Elbows

PEL-90MM (m/m 90º Elbow)

PEL-90FF ( f/f 90º Elbow)

PEL-90FM ( f/m 90º Elbow)

PEL-45FM ( f/m 45º Elbow)

F - Support Ring & Plate PSPXT-8
G - Firestop

FS-8

H - Heat Shield

RHS101

HeatShields
Installing a Wall Mounted RHS101 Heat shield

The RHS101 Heat shield

mustbeusedifventpipepassesthrough

awallorceilingwithin6'oftheunit.
To install the RHS101, Slide the Inner Section over the vent pipe

that will connect to the fireplace. Then fasten the vent pipe to the

back of the fireplace with a minimum of three sheet metal screws.

From the outside slide the RHS101 outer section on. To complete

the installation fasten the Heat Shield Outer Section & inner section

to the structure. See Figure 8 Sec.4.

Figure 8 Sec.4 RHS101 Installation. (Install by sliding over vent pipe

where it passes through the combustible construction).

Outer Shield 10 1/4”

3/8” Min. Both sides Typical

3/8” Min.

3/8” Min .

Combustible Framing

12” x 12”

Inner Shield 9 3/8”

R320-ST & R420-ST Power Vent Indoor Gas Fireplace

Page 16

XG0774 - 150121