Troubleshooting

The following is a troubleshooting chart of possible problems:

PROBLEM

CORRECTIVE ACTION

Noisy Pilot Flame

Locate pilot adjustment screw on gas

control valve. The flame is decreased

by turning adjustment screw clock-

wise.

Pilot won’t ignite

Disconnect remote wires and try to

light pilot. If pilot now works, remote

connections are faulty. Check wiring

diagram figure 13.

Main burner will

1. Check wiring (see figure 13).

not light

2. Check wall switch for proper con-

nection.

3. Check high limit switch.

If your fireplace still does not operate correctly, consult your dealer or the manufacturer.

All service and repairs should be performed by a qualified agency.

All spare parts and optional such as trim finishes and the wireless infrared remote control are available from your local dealer or the

manufacturer.

Replacement Parts

Standing Pilot - Replacement Parts List

Hotshot DHS Insert

NG Gas Valve

RGC1044R

LP Gas Valve

RGC1043R

NG Pilot

RPA024

LP Pilot

RPA025

NG Burner

Contact Local Montigo Dealer

LP Burner
Thermocouple

RPG001

Thermopile

RPG001

Piezo Ignitor

PIEZO

Pilot Tubing

RPTA03

Door

RDHS

Replacement Screen

RSCDHS

Log Set

RLGS19