Installation

Installing The Gas Line

The gas line must be installed before finishing the Hotshot DHS insert.

For ease of installation, this appliance is equipped with an approved

flexible gas connector. The connector is factory-installed and can be

connected to the gas line as shown in figure 3.
Natural Gas requires a minimum inlet gas supply pressure of 5.5"

W.C. & a manifold pressure of 3.5" W.C. Propane Gas requires a

minimum inlet gas supply pressure of 11" W.C. & a manifold pressure

of 10" W.C. The fireplace gas connection and the main operating gas

valve is located behind the removable brass trim at the bottom of the

unit and need only be attached to the gas line with an approved fit-

ting, as required by the applicable installation codes.
• Only use gas shut-off valves approved for use by the state, province,

region, or governing body, in which the appliance is being installed, or

as required by the applicable installation codes.
The appliance and its individual shutoff valve must be disconnected

from the gas supply piping system during any pressure testing of that

system at test pressures in excess of 1/2 psig (3.5 kPa).
The appliance must be isolated from the gas supply piping system by

closing its individual manual shutoff valve during any pressure testing

of the gas supply piping system at test pressures equal to or less than

1/2 psig (3.5 kPa).

Figure 3. Gas line location.

Note: After the gas line is connected, each appliance con-

nection, valve and valve train must be checked while

under normal operating pressure with either a liquid

solution, or leak detection device, to locate any source

of leak. Tighten any areas where bubbling appears or

leak is detected until bubbling stops completely or leak

is no longer detected. DO NOT use a flame of any

kind to test for leaks.

3/8” flexible

gas connector

3 1/8”

1 3/8”

Clearances

The Hotshot DHS clearances to combustible materials:

Perpendicular Wall

3"

Mantle

10 ½"

Refer to figure 2.

The Hotshot DHS must be installed in a masonry or factory-built

solid fuel fireplace with a hearth extending 16" from the fireplace

facing. This appliance is not for installation in air tight units.

Top of fireplace

Combustible

Construction allowed

in shaded area

Horizontal Run (in.)

Ve

rtical Height (in.)

24 22 20 18 16 14 12 10 8 6 4 2

12

10

8

6

4

2

16

14

20

18

24

22

28

26

32

30

10

8

8

20

2 ½

Figure 2. Mantle clearances.