22
CONNECTING CONTROL OUTPUTS TO THE HVR
Each HVR unit may have up to 4 Control Outputs. These outputs can be used to trigger devices such as Sirens, Phone Dialers,
Lights, and any other relay activated device. There is no power supplied to the ports. Use an external power supply if necessary.
8/16 Channel
4 Channel
Use 12V, below 300mA. For controlling lights or other devices, use another external relay.
Maximum voltage is 24V AC @ 1 amp
Output uses a Form C Relay
Siren, Alarm, Outside Relays
(Common)
(Common)
External Power Supply (DC 12V)
(+)
(-)
Siren, Alarm, Outside Relays
External Power Supply (DC 12V)