8-Advanced Function of Oscilloscope

The following Table describes the Vertical Channel menu:

Function

menu

Setting

Description

Coupling

AC
DC

Ground

The DC component in the input signal is blocked..
The AC and DC components of the input signal are allowed.
Input signal is interrupted.

Channel

OFF

ON

Close the channel.
Open the channel.

Probe

1X

10X

100X

1000X

Select one according the probe attenuation factor to ensure a correct
vertical scale reading.

Inverted

OFF

ON

Waveform is displayed normally.
Open the Invert function of the waveform setting.

8.2.1 Setting the Channel Coupling

With CH1 taken for example, the measured signal is a sine wave signal containing a DC offset.
Press F1 Coupling first and then AC to make an ac coupling setting. The DC component
contained in the tested signal is blocked.

Press F1 Coupling first and then DC to make a DC coupling setting. Both dc and ac components
contained in the tested signal are permitted.

The waveform is displayed as the following figure 35, figure 36.

figure 35: AC Coupling