Lpg (g 30 - g 31) і – Ravenheat CSI 85 User Manual

Page 9

Advertising
background image

SECTION 3

TECHNICAL DATA

CSI 85 (T) 780 Series

TABLE 1/A

LPG (G 30 - G 31)

І

3+

-

П

2H3+

NOMINAL HEAT INPUT NET QMS

24.8 kW

MINIMUM HEAT INPUT NET

13.0 kW

9

NOMINAL HEAT OUTPUT

23.8 kW

NOMINAL HEAT OUTPUT CONDENSING

26.2 kW

MINIMUM HEAT OUTPUT

10.6 kW

MINIMUM HEAT OUTPUT CONDENSING

13.7 kW

GAS RATE

max

G31 0.9 m

3

/h G30 0.7 m

3

/h

AFTER 10 MINUTES

min

0.5 m

3

/h 0.4 m

3

/h

INLET PRESSURE

G31 37mbar G30 28-30 mbar

BURNER PRESSURE C.H.

max

G31 35.4mbar G30 27.3 mbar

min

7.3 mbar 7.0 mbar

MAIN BURNER INJECTORS

Nr 13 x 0.75

ELECTRICAL SUPPLY

230 V ~ 50 HZ

POWER CONSUMPTION

150 W

EXTERNAL FUSE RATING

3A

INTERNAL FUSE

3.15 A

(20 mm to BS 4265)

DRY WEIGHT

46 kg

WATER CONTENT C.H.

2.1 litre

WATER CONTENT

0.5 litre

GAS SUPPLY CONNECTION

15 mm compression isolating valve

FLOW CONNECTION C.H.

22 mm compression isolating valve

RETURN CONNECTION C.H.

22 mm compression isolating valve

INLET CONNECTION D.H.W.

15 mm compression isolating valve

OUTLET CONNECTION D.H.W.

15 mm compression

SAFETY DISCHARGE C.H.

15 mm copper pipe

CONDENSATION DRAIN

3/4” (21.5 mm) push fi t over fl ow

MAX COLD WATER CAPACITY WITHOUT ADDITIONAL EXPANSION VESSEL 110 LITRE

SEALED WATER SYSTEM C.H.
MAX PRESSURE PHS

2.5 bar

MINIMUM WORKING PRESSURE

0.5 bar

6 LITRES EXPANSION VESSEL PRE-CHARGE-PRESSURE

0.5 bar

CENTRAL HEATING OPERATING TEMPERATURE MAX 85°C MIN 35°C

DESIGN FLOW RATE 1102 I/h 20 °C RISE
MINIMUM FLOW RATE C.H. 503 I/min
D.H.W. FLOW RATE 30 °C rise

13.2 l/min

D.H.W. FLOW RATE 35 °C rise

11.0 l/min

D.H.W. FLOW RATE 40 °C rise

9.9 l/min 10°C inlet temperature

D.H.W. TEMPERATURE

max 65 °C min 35 °C

BURNER PRESSURE D.H.W.

MAX G31 35.4 - G30 27.3 mbar
MIN G31 7.3 - G30 7.0 mbar

Qmw Imput Net MAX 26.0 kW - MIN 13.0 kW
D.H.W. PRESSURE

max 10 bar (147 p.s.i.)

D.H.W. PRESSURE PMW

min 0.8 bar (11.8 p.s.i.) To obtain heat input 1.2 bar

D.H.W. MINIMUM FLOW RATE

3 I/min

FLUE OUTLET NOM. DIAMETER 100 mm specially supplied with boilers
DESTINATION: BE, FR

CATEGORY I

2H+

DESTINATION: GB, IE, CH, ES, IT, PT

CATEGORY II

2H3+

FLUE TYPE - C

12

- C

32

- C

52

NOX

4

Advertising