CMF Series

We offer two different indoor-unit
designs.
The wall-mounted CMF Series is
equipped with a circulation pump
and a safety module on the water
side. Furthermore, an electrical
booster heater can be incorporated
as an option.

The CMF Series was constructed for
the addition of several heat sources
(bivalent installations or systems
with solar-heating equipment).
External buffer storage is always
required, its size depending on the
type and the power of the second
heat source. On the one hand,

the buffer storage prevents short
run-times for the heat pump and
on the other hand, that sufficient
defrosting energy is available.

Versions

CMF Series

Safety assembly

Pipe assembly for the installation of

the optional electric

supplemental heating

Fold-down electrical

control box
Terminal block X3 for the

temperature sensor
Relays with indicator lights
Terminal block X2 for external components,

such as heating-circuit pumps, etc.
Unoccupied space for circuit breakers

for the optional electric booster heater
Terminal block X1 for the power supply

to the indoor module

Mode switch

Identification plate and quick-reference

guide are found inside the hinged panel

11